Product Details:
|
Product Name: | Malaria Pf/Pan Rapid Test | Formats: | Cassette |
---|---|---|---|
Reaction Time: | 10-15 Minutes | Shelf Life: | 24 Months At Room Temperature 4- 30 Degrees |
Others: | The Kits Can Be Made According To The Customers' Artwork Or Design | Time Of Use: | Disposable |
Highlight: | Whole Blood Malaria Pf/Pan Rapid Test,Malaria Pf/Pan Rapid Test Cassette |
The Malaria Pf/Pan Rapid Test Device is a rapid chromatographic immunoassay for the qualitative detection of circulating antigens of Plasmodium falciparum, Plasmodium vivax, Plasmodium ovale, Plasmodium malariae in whole blood.
Detection Principle
The Malaria Pf/Pan Rapid Test Device (Whole Blood) is a qualitative, membrane based immunoassay for the detection of P.f, P.v, P.o and P.m antigens in whole blood. The membrane is pre‐coated with anti‐HRP‐II antibodies and anti‐Lactate Dehydrogenase antibodies. During testing, the whole blood specimen reacts with the dye conjugate, which has been pre‐coated on the test strip. The mixture then migrates upward on the membrane by capillary action, reacts with anti‐Histidine‐Rich Protein II (HRP‐II) antibodies on the membrane on P.f Test Line region and with anti‐Lactate Dehydrogenase antibodies on the membrane on Pan Line region. If the specimen contains HRP‐II or Plasmodium‐ specific Lactate Dehydrogenase or both, a colored line will appear in P.f line region or Pan line region or two colored lines will appear in P.f line region and Pan line region. The absence of the colored lines in P.f line region or Pan line region indicates that the specimen does not contain HRP‐II and/or Plasmodium‐specific Lactate Dehydrogenase. To serve as a procedure control, a colored line will always appear in the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred.
STORAGE AND STABILITY
The kit can be stored at room temperature or refrigerated (2‐30°C). The test device is stable through the expiration date printed on the sealed pouch. The test device must remain in the sealed pouch until use. DO NOT FREEZE. Do not use beyond the expiration date.
PROCEDURE
Allow the test device, specimen, buffer, and/or controls to equilibrate to room temperature (15‐30°C) prior to testing.
3. Wait for the colored line(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.
INTERPRETATION OF RESULTS
LIMITATIONS OF THE TEST
KIT COMPONENTS
MATERIALS REQUIRED BUT NOT PROVIDED
Contact Person: Mr. Kayla YI
Tel: +86 13760822077